{\rtf1\ansi\ansicpg1252\deff0
{\fonttbl
\f0\froman\fcharset0 Times;
\f1\fswiss\fcharset0 Helvetica;
\f2\fmodern\fcharset0 Courier;
\f3\ftech\fcharset2 Symbol;
\f4\fnil\fcharset0 Times new roman;
}
{\colortbl
;
\red127\green255\blue212;
\red0\green0\blue0;
\red0\green0\blue255;
\red255\green0\blue255;
\red190\green190\blue190;
\red0\green255\blue0;
\red50\green205\blue50;
\red176\green48\blue96;
\red0\green0\blue128;
\red85\green107\blue47;
\red160\green32\blue240;
\red255\green0\blue0;
\red192\green192\blue192;
\red0\green128\blue128;
\red255\green255\blue255;
\red255\green255\blue0;
}
{\info
{\*\userprops
{\propname creator}\proptype30
{\staticval XMLmind FO Converter}
}
}
\facingp\margmirror\fet0\ftnbj
\sectd
\pghsxn15840\pgwsxn12240
\margtsxn1440\margbsxn1440\marglsxn1800\margrsxn1800
\margmirsxn
\pgnrestart\pgnstarts1\pgndec
{\headerr
\pard\plain\f0\fs57
\par
\trowd\trleft0
\clvertalt
\cellx3600
\clvertalt
\cellx8640
\clvertalt
\cellx12240
\pard\intbl\li1800\sl250
{\plain\f4\fs21\cf2
IAC 1/27/21
}
\cell
\pard\intbl\qc\sl250
{\plain\f4\fs21\cf2
Public Safety[661]
}
\cell
\pard\intbl\qr\ri1800\sl250
{\plain\f4\fs21\cf2
Ch
}
{\plain\f4\fs21\cf2
, p.
}
{\plain\f4\fs21\cf2
\chpgn
}
\cell
\row
}
{\headerl
\pard\plain\f0\fs57
\par
\trowd\trleft0
\clvertalt
\cellx3600
\clvertalt
\cellx8640
\clvertalt
\cellx12240
\pard\intbl\li1800\sl250
{\plain\f4\fs21\cf2
Ch
}
{\plain\f4\fs21\cf2
, p.
}
{\plain\f4\fs21\cf2
\chpgn
}
\cell
\pard\intbl\qc\sl250
{\plain\f4\fs21\cf2
Public Safety[661]
}
\cell
\pard\intbl\qr\ri1800\sl250
{\plain\f4\fs21\cf2
IAC 1/27/21
}
\cell
\row
}
{\footerr
}
{\footerl
}
\pard\keepn\sb57\qc\sl250
{\plain\f4\fs21\cf2
CHAPTER
}
{\plain\f4\fs21\cf2
157
}
\par
\pard\qc\sl250
{\plain\f4\fs21\cf2
DEVICES AND METHODS TO TEST BODY FLUIDS FOR ALCOHOL OR DRUGS
}
\par
\pard\sb210\qj\sl250
{\plain\f4\fs21\b\cf2\ulc2
661—157.
}
{\plain\f4\fs21\b\cf2\ulc2
1
}
{\plain\f4\fs21\b\cf2\ulc2
(321J)
}
{\plain\f4\fs21\b\cf2\ulc2
Approval of devices and methods to test for alcohol or drug concentration.
}
{\plain\f4\fs21\b\cf2\ulc2
}
{\plain\f4\fs21\cf2\ulc2
The commissioner, by these rules, approves the following devices and methods to take a specimen of a person’s breath or urine for the purpose of determining the alcohol or drug concentration.
}
\par
\pard\sb210\qj\sl250
{\plain\f4\fs21\b\cf2\ulc2
661—157.
}
{\plain\f4\fs21\b\cf2\ulc2
2
}
{\plain\f4\fs21\b\cf2\ulc2
(321J)
}
{\plain\f4\fs21\b\cf2\ulc2
Evidentiary breath testing.
}
\par
\pard\qj\sl250\tx340
{\plain\f4\fs21\cf2\ulc2
\tab
}
{\plain\f4\fs21\b\cf2\ulc2
157.2
}
{\plain\f4\fs21\b\cf2\ulc2
(1)
}
{\plain\f4\fs21\cf2\ulc2
}
{\plain\f4\fs21\cf2\ulc2
A breath testing device is a device designed and constructed to measure a subject’s breath alcohol concentration by utilizing a sample of the subject’s breath.
}
\par
\pard\qj\sl250\tx340\tx40\tx40
{\plain\f4\fs21\cf2\ulc2
\tab
}
{\plain\f4\fs21\b\cf2\ulc2
157.2
}
{\plain\f4\fs21\b\cf2\ulc2
(2)
}
{\plain\f4\fs21\cf2\ulc2
}
{\plain\f4\fs21\cf2\ulc2
A peace officer desiring to perform testing of a subject’s breath for the purpose of determining the alcohol concentration shall employ, or cause to be used, a breath testing device of a type meeting the minimum performance requirements established in Highway Safety Programs; Model Specifications for Devices to Measure Breath Alcohol, Federal Register, Volume 58, No.
}
{\plain\f4\fs21\cf2\ulc2
\tab
}
{\plain\f4\fs21\cf2\ulc2
179 (September 17, 1993), pp.
}
{\plain\f4\fs21\cf2\ulc2
\tab
}
{\plain\f4\fs21\cf2\ulc2
48705-48708. All devices so used must be certified to be in proper working order at least once per calendar year according to procedures specified for that device. The interval between certifications shall not be more than 450 days.
}
\par
\pard\qj\sl250\tx340
{\plain\f4\fs21\cf2\ulc2
\tab
}
{\plain\f4\fs21\b\cf2\ulc2
157.2
}
{\plain\f4\fs21\b\cf2\ulc2
(3)
}
{\plain\f4\fs21\cf2\ulc2
}
{\plain\f4\fs21\cf2\ulc2
The division of criminal investigation criminalistics laboratory shall maintain a list of devices approved by the commissioner of public safety for collection of breath samples for evidentiary purposes. The current list shall be available upon request to the Division of Criminal Investigation Criminalistics Laboratory at 2240 South Ankeny Boulevard, Ankeny, Iowa 50023, or on the website of the department of public safety.
}
\par
\pard\qj\sl250\tx340
{\plain\f4\fs21\cf2\ulc2
\tab
}
{\plain\f4\fs21\b\cf2\ulc2
157.2
}
{\plain\f4\fs21\b\cf2\ulc2
(4)
}
{\plain\f4\fs21\cf2\ulc2
}
{\plain\f4\fs21\cf2\ulc2
The operator of an evidentiary breath testing device shall have been certified as competent in the operation of the breath testing device and shall proceed in accordance with the instructions included in an operating manual furnished by the division of criminal investigation criminalistics laboratory. An operating manual, with number and date, specific to a particular approved device and prepared by the division of criminal investigation criminalistics laboratory shall be available to operators using the device. The current version of the operating manual for each device currently approved for use in Iowa may be obtained by contacting the Division of Criminal Investigation Criminalistics Laboratory at 2240 South Ankeny Boulevard, Ankeny, Iowa 50023, or from the department’s website.
}
\par
\pard\qj\sl250\tx340
{\plain\f4\fs21\cf2\ulc2
\tab
}
{\plain\f4\fs21\b\cf2\ulc2
157.2
}
{\plain\f4\fs21\b\cf2\ulc2
(5)
}
{\plain\f4\fs21\cf2\ulc2
}
{\plain\f4\fs21\cf2\ulc2
All certifications of evidentiary breath testing devices shall be made by the division of criminal investigation criminalistics laboratory. All certifications of operators shall be made by the division of criminal investigation criminalistics laboratory or a designee. A designee shall be a person trained and certified by the division of criminal investigation criminalistics laboratory.
}
\par
\pard\keep\sl180
{\plain\f4\fs16\cf2
[
}
{\field{\*\fldinst HYPERLINK "https://www.legis.iowa.gov/docs/aco/arc/7529B.pdf"}{\fldrslt
{\plain\f4\fs16\b\cf2
ARC 7529B
}
}}
{\plain\f4\fs16\cf2
, IAB 1/28/09, effective 4/1/09;
}
{\field{\*\fldinst HYPERLINK "https://www.legis.iowa.gov/docs/aco/arc/0219C.pdf"}{\fldrslt
{\plain\f4\fs16\b\cf2
ARC 0219C
}
}}
{\plain\f4\fs16\cf2
, IAB 7/25/12, effective 9/1/12;
}
{\field{\*\fldinst HYPERLINK "https://www.legis.iowa.gov/docs/aco/arc/5407C.pdf"}{\fldrslt
{\plain\f4\fs16\b\cf2
ARC 5407C
}
}}
{\plain\f4\fs16\cf2
, IAB 1/27/21, effective 3/3/21]
}
\par
\pard\sb210\qj\sl250
{\plain\f4\fs21\b\cf2\ulc2
661—157.
}
{\plain\f4\fs21\b\cf2\ulc2
3
}
{\plain\f4\fs21\b\cf2\ulc2
(321J)
}
{\plain\f4\fs21\b\cf2\ulc2
Urine collection.
}
{\plain\f4\fs21\b\cf2\ulc2
}
{\plain\f4\fs21\cf2\ulc2
A peace officer who collects a sample of a subject’s urine for the purpose of determining alcohol or drug concentration shall proceed as follows.
}
\par
\pard\qj\sl250\tx340
{\plain\f4\fs21\cf2\ulc2
\tab
}
{\plain\f4\fs21\b\cf2\ulc2
157.3
}
{\plain\f4\fs21\b\cf2\ulc2
(1)
}
{\plain\f4\fs21\cf2\ulc2
}
{\plain\f4\fs21\cf2\ulc2
The collection shall be made in the presence of a peace officer or other reliable person under the supervision of a peace officer. The peace officer or other person in the presence of the subject shall be of the same gender as the subject.
}
\par
\pard\qj\sl250\tx340
{\plain\f4\fs21\cf2\ulc2
\tab
}
{\plain\f4\fs21\b\cf2\ulc2
157.3
}
{\plain\f4\fs21\b\cf2\ulc2
(2)
}
{\plain\f4\fs21\cf2\ulc2
}
{\plain\f4\fs21\cf2\ulc2
As soon as practicable, the subject shall urinate into a urine alcohol kit-supplied bottle, cup or other suitable container which is clean, dry, and free from any visible contamination. Anticoagulant and antimicrobial substances in a blood or urine kit do not constitute visible contamination.
}
\par
\pard\qj\sl250\tx340
{\plain\f4\fs21\cf2\ulc2
\tab
}
{\plain\f4\fs21\b\cf2\ulc2
157.3
}
{\plain\f4\fs21\b\cf2\ulc2
(3)
}
{\plain\f4\fs21\cf2\ulc2
}
{\plain\f4\fs21\cf2\ulc2
The peace officer shall collect a second urine void for alcohol testing in a suitable container which is clean, dry, and free from visible contamination. If a second void cannot be collected, the peace officer shall submit a sample from the first void and shall inform the Iowa division of criminal investigation criminalistics laboratory on the laboratory receipt form that the sample is from a first void. It is not necessary that the subject’s bladder be completely emptied.
}
\par
\pard\qj\sl250\tx340
{\plain\f4\fs21\cf2\ulc2
\tab
}
{\plain\f4\fs21\b\cf2\ulc2
157.3
}
{\plain\f4\fs21\b\cf2\ulc2
(4)
}
{\plain\f4\fs21\cf2\ulc2
}
{\plain\f4\fs21\cf2\ulc2
When collection of the sample for alcohol testing has been completed, the peace officer shall cause a portion of the collected sample to be transferred to a test tube containing 100 milligrams of sodium fluoride and anticoagulant.
}
\par
\pard\qj\sl250\tx340
{\plain\f4\fs21\cf2\ulc2
\tab
}
{\plain\f4\fs21\b\cf2\ulc2
157.3
}
{\plain\f4\fs21\b\cf2\ulc2
(5)
}
{\plain\f4\fs21\cf2\ulc2
}
{\plain\f4\fs21\cf2\ulc2
A listing of test kits known to meet the requirements of subrules
}
{\field{\*\fldinst HYPERLINK "https://www.legis.iowa.gov/docs/iac/rule/661.157.3.pdf"}{\fldrslt
{\plain\f4\fs21\cf2\ulc2
157.3(2)
}
}}
{\plain\f4\fs21\cf2\ulc2
,
}
{\field{\*\fldinst HYPERLINK "https://www.legis.iowa.gov/docs/iac/rule/661.157.3.pdf"}{\fldrslt
{\plain\f4\fs21\cf2\ulc2
157.3(3)
}
}}
{\plain\f4\fs21\cf2\ulc2
and
}
{\field{\*\fldinst HYPERLINK "https://www.legis.iowa.gov/docs/iac/rule/661.157.3.pdf"}{\fldrslt
{\plain\f4\fs21\cf2\ulc2
157.3(4)
}
}}
{\plain\f4\fs21\cf2\ulc2
may be found on the criminalistics laboratory website. Any peace officer wishing to use a test kit which is not listed should inquire of the criminalistics laboratory as to whether the other test kit meets the requirements. Any provider of test kits may request the addition of a kit to the list by sending a sample kit to the administrator of the criminalistics laboratory with a cover letter requesting that the kit be added to the list of kits known to meet the requirements of this subrule.
}
\par
\pard\qj\fi340\sl250
{\plain\f4\fs21\scaps\cf2\ulc2
Note:
}
{\plain\f4\fs21\cf2\ulc2
The current location of information about test kits on the laboratory website is:
}
{\field{\*\fldinst HYPERLINK "https://dps.iowa.gov/divisions/criminal-investigation/criminalistics-laboratory/toxicology"}{\fldrslt
{\plain\f4\fs21\ul\cf2\ulc2
dps.iowa.gov/divisions/criminal-investigation/criminalistics-laboratory/toxicology
}
}}
{\plain\f4\fs21\cf2\ulc2
.
}
\par
\pard\qj\sl250\tx340
{\plain\f4\fs21\cf2\ulc2
\tab
}
{\plain\f4\fs21\b\cf2\ulc2
157.3
}
{\plain\f4\fs21\b\cf2\ulc2
(6)
}
{\plain\f4\fs21\cf2\ulc2
}
{\plain\f4\fs21\cf2\ulc2
If the peace officer requests additional toxicological testing, the remainder of the sample may be retained in a container and sent for analysis to the Iowa division of criminal investigation criminalistics laboratory.
}
\par
\pard\qj\sl250\tx340
{\plain\f4\fs21\cf2\ulc2
\tab
}
{\plain\f4\fs21\b\cf2\ulc2
157.3
}
{\plain\f4\fs21\b\cf2\ulc2
(7)
}
{\plain\f4\fs21\cf2\ulc2
}
{\plain\f4\fs21\cf2\ulc2
The peace officer shall label the container showing the date and time the sample was collected and identifying the peace officer, the subject, and the person present during the collection of the sample if other than the peace officer.
}
\par
\pard\sb210\qj\sl250
{\plain\f4\fs21\b\cf2\ulc2
661—157.
}
{\plain\f4\fs21\b\cf2\ulc2
4
}
{\plain\f4\fs21\b\cf2\ulc2
(321J)
}
{\plain\f4\fs21\b\cf2\ulc2
Submission of samples for alcohol and drug testing to the criminalistics laboratory.
}
{\plain\f4\fs21\b\cf2\ulc2
}
{\plain\f4\fs21\cf2\ulc2
Any sample of urine or blood may be submitted to the division of criminal investigation criminalistics laboratory or other appropriate laboratory via ordinary mail, private courier, or personal delivery.
}
\par
\pard\sb210\qj\sl250
{\plain\f4\fs21\b\cf2\ulc2
661—157.
}
{\plain\f4\fs21\b\cf2\ulc2
5
}
{\plain\f4\fs21\b\cf2\ulc2
(321J)
}
{\plain\f4\fs21\b\cf2\ulc2
Preliminary breath screening test.
}
\par
\pard\qj\sl250\tx340
{\plain\f4\fs21\cf2\ulc2
\tab
}
{\plain\f4\fs21\b\cf2\ulc2
157.5
}
{\plain\f4\fs21\b\cf2\ulc2
(1)
}
{\plain\f4\fs21\cf2\ulc2
}
{\plain\f4\fs21\cf2\ulc2
A peace officer desiring to perform a preliminary screening test of a person’s breath shall use a device approved by the division of criminal investigation criminalistics laboratory. Such devices are approved for accuracy and precision using a dry gas standard or breath simulating device. The division of criminal investigation criminalistics laboratory shall employ scientifically established tests or methods appropriate to a particular device in determining whether the device meets an acceptable standard for operation including accuracy, or the laboratory may, at its discretion, accept test results from another laboratory. The standards shall include the requirement that in all cases the device shall indicate the alcohol concentration on a numerical display. Devices shall be of a type that may be calibrated on a monthly basis by officers in the field.
}
\par
\pard\qj\fi340\sl250
{\plain\f4\fs21\cf2\ulc2
The division of criminal investigation criminalistics laboratory shall maintain a list of devices approved by the commissioner for use as preliminary breath screening devices. The list of currently approved devices is available on the website of the department.
}
\par
\pard\qj\sl250\tx340
{\plain\f4\fs21\cf2\ulc2
\tab
}
{\plain\f4\fs21\b\cf2\ulc2
157.5
}
{\plain\f4\fs21\b\cf2\ulc2
(2)
}
{\plain\f4\fs21\cf2\ulc2
}
{\plain\f4\fs21\cf2\ulc2
Any peace officer using an approved device shall follow the instructions furnished by the manufacturer for use of such a device. The calibration of each unit shall be checked at least once per month, and the device shall be calibrated, if necessary, using a dry gas standard. The officer or officer’s department shall maintain a record of each calibration. This record shall include:
}
\par
\pard\qj\sl250\tx340\tx680
{\plain\f4\fs21\cf2\ulc2
\tab
}
{\plain\f4\fs21\i\cf2\ulc2
a.
}
{\plain\f4\fs21\cf2\ulc2
\tab
}
{\plain\f4\fs21\cf2\ulc2
The identity of the person performing the calibration.
}
\par
\pard\qj\sl250\tx340\tx680
{\plain\f4\fs21\cf2\ulc2
\tab
}
{\plain\f4\fs21\i\cf2\ulc2
b.
}
{\plain\f4\fs21\cf2\ulc2
\tab
}
{\plain\f4\fs21\cf2\ulc2
The date.
}
\par
\pard\qj\sl250\tx340\tx680
{\plain\f4\fs21\cf2\ulc2
\tab
}
{\plain\f4\fs21\i\cf2\ulc2
c.
}
{\plain\f4\fs21\cf2\ulc2
\tab
}
{\plain\f4\fs21\cf2\ulc2
The value of standard used.
}
\par
\pard\qj\sl250\tx340\tx680
{\plain\f4\fs21\cf2\ulc2
\tab
}
{\plain\f4\fs21\i\cf2\ulc2
d.
}
{\plain\f4\fs21\cf2\ulc2
\tab
}
{\plain\f4\fs21\cf2\ulc2
The unit type and identification number.
}
\par
\pard\qj\sl250\tx340\tx680
{\plain\f4\fs21\cf2\ulc2
\tab
}
{\plain\f4\fs21\i\cf2\ulc2
e.
}
{\plain\f4\fs21\cf2\ulc2
\tab
}
{\plain\f4\fs21\cf2\ulc2
The expiration date of the standard used.
}
\par
\pard\keep\sl180
{\plain\f4\fs16\cf2
[
}
{\field{\*\fldinst HYPERLINK "https://www.legis.iowa.gov/docs/aco/arc/5407C.pdf"}{\fldrslt
{\plain\f4\fs16\b\cf2
ARC 5407C
}
}}
{\plain\f4\fs16\cf2
, IAB 1/27/21, effective 3/3/21]
}
\par
\pard\sb210\qj\sl250
{\plain\f4\fs21\b\cf2\ulc2
661—157.
}
{\plain\f4\fs21\b\cf2\ulc2
6
}
{\plain\f4\fs21\b\cf2\ulc2
(123)
}
{\plain\f4\fs21\b\cf2\ulc2
Chemical test—alcohol concentration—public intoxication.
}
{\plain\f4\fs21\b\cf2\ulc2
}
{\plain\f4\fs21\cf2\ulc2
All devices and methods approved in this chapter for the purpose of determining a person’s alcohol concentration for evidential purposes under Iowa Code chapter
}
{\field{\*\fldinst HYPERLINK "https://www.legis.iowa.gov/docs/ico/chapter/321J.pdf"}{\fldrslt
{\plain\f4\fs21\cf2\ulc2
321J
}
}}
{\plain\f4\fs21\cf2\ulc2
, and the devices otherwise approved in this chapter only for use in performing preliminary breath screening tests, are equally approved for testing to determine alcohol concentration in connection with arrests for public intoxication under Iowa Code section
}
{\field{\*\fldinst HYPERLINK "https://www.legis.iowa.gov/docs/ico/section/123.46.pdf"}{\fldrslt
{\plain\f4\fs21\cf2\ulc2
123.46
}
}}
{\plain\f4\fs21\cf2\ulc2
. The chemical test results shall be expressed in terms of alcohol concentration as defined in Iowa Code section
}
{\field{\*\fldinst HYPERLINK "https://www.legis.iowa.gov/docs/ico/section/321J.1.pdf"}{\fldrslt
{\plain\f4\fs21\cf2\ulc2
321J.1
}
}}
{\plain\f4\fs21\cf2\ulc2
.
}
\par
\pard\sb210\qj\sl250
{\plain\f4\fs21\b\cf2\ulc2
661—157.
}
{\plain\f4\fs21\b\cf2\ulc2
7
}
{\plain\f4\fs21\b\cf2\ulc2
(321J)
}
{\plain\f4\fs21\b\cf2\ulc2
Detection of drugs other than alcohol.
}
\par
\pard\qj\sl250\tx340
{\plain\f4\fs21\cf2\ulc2
\tab
}
{\plain\f4\fs21\b\cf2\ulc2
157.7
}
{\plain\f4\fs21\b\cf2\ulc2
(1)
}
{\plain\f4\fs21\cf2\ulc2
}
{\plain\f4\fs21\i\cf2\ulc2
Adoption of federal standards.
}
{\plain\f4\fs21\cf2\ulc2
}
{\plain\f4\fs21\cf2\ulc2
Initial test requirements based upon standards adopted by the federal Substance Abuse and Health Services Administration in “Mandatory Guidelines for Federal Workplace Drug Testing Programs,” 82 FR 7920, and displayed in the following table are hereby adopted as standards for determining detectable levels of controlled substances in the division of criminal investigation criminalistics laboratory initial screening for controlled substances detected by the presence of the following: marijuana metabolites, cocaine metabolites, codeine/morphine, hydrocodone/hydromorphone, oxycodone/oxymorphone, 6-acetylmorphine, phencyclidine, amphetamine/methamphetamine, and MDMA/MDA. The following table shows the minimum levels of these substances which will result in a finding that a controlled substance is present at a detectable level:
}
\par
\pard\plain\f0\fs18
\par
\trowd\trleft5
\clpadft3\clpadt80
\clpadfb3\clpadb80
\clpadfl3\clpadl80
\clpadfr3\clpadr80
\clvertalc
\clbrdrt\brdrs\brdrw10\brdrcf2\clbrdrb\brdrs\brdrw10\brdrcf2\clbrdrl\brdrs\brdrw10\brdrcf2\clbrdrr\brdrs\brdrw10\brdrcf2\cellx3705
\clpadft3\clpadt80
\clpadfb3\clpadb80
\clpadfl3\clpadl80
\clpadfr3\clpadr80
\clvertalt
\clbrdrt\brdrs\brdrw10\brdrcf2\clbrdrb\brdrs\brdrw10\brdrcf2\clbrdrr\brdrs\brdrw10\brdrcf2\cellx6087
\pard\intbl\qc\li80\ri90\sl200
{\plain\f4\fs18\cf2\ulc2
Initial test analyte
}
\cell
\pard\intbl\qc\li80\ri80\sl200
{\plain\f4\fs18\cf2\ulc2
Initial test cutoff1
}
\cell
\row
\trowd\trleft5
\clpadft3\clpadt80
\clpadfb3\clpadb80
\clpadfl3\clpadl80
\clpadfr3\clpadr80
\clvertalt
\clbrdrb\brdrs\brdrw10\brdrcf2\clbrdrl\brdrs\brdrw10\brdrcf2\clbrdrr\brdrs\brdrw10\brdrcf2\cellx3705
\clpadft3\clpadt80
\clpadfb3\clpadb80
\clpadfl3\clpadl80
\clpadfr3\clpadr80
\clvertalt
\clbrdrb\brdrs\brdrw10\brdrcf2\clbrdrr\brdrs\brdrw10\brdrcf2\cellx6087
\pard\intbl\li80\ri90\sl200
{\plain\f4\fs18\cf2\ulc2
Marijuana metabolites (THCA)2
}
\cell
\pard\intbl\qc\li80\ri80\sl200
{\plain\f4\fs18\cf2\ulc2
50 ng/ml3
}
\cell
\row
\trowd\trleft5
\clpadft3\clpadt80
\clpadfb3\clpadb80
\clpadfl3\clpadl80
\clpadfr3\clpadr80
\clvertalt
\clbrdrb\brdrs\brdrw10\brdrcf2\clbrdrl\brdrs\brdrw10\brdrcf2\clbrdrr\brdrs\brdrw10\brdrcf2\cellx3705
\clpadft3\clpadt80
\clpadfb3\clpadb80
\clpadfl3\clpadl80
\clpadfr3\clpadr80
\clvertalt
\clbrdrb\brdrs\brdrw10\brdrcf2\clbrdrr\brdrs\brdrw10\brdrcf2\cellx6087
\pard\intbl\li80\ri90\sl200
{\plain\f4\fs18\cf2\ulc2
Cocaine metabolites (Benzoylecgonine)
}
\cell
\pard\intbl\qc\li80\ri80\sl200
{\plain\f4\fs18\cf2\ulc2
150 ng/ml3
}
\cell
\row
\trowd\trleft5
\clpadft3\clpadt80
\clpadfb3\clpadb80
\clpadfl3\clpadl80
\clpadfr3\clpadr80
\clvertalt
\clbrdrb\brdrs\brdrw10\brdrcf2\clbrdrl\brdrs\brdrw10\brdrcf2\clbrdrr\brdrs\brdrw10\brdrcf2\cellx3705
\clpadft3\clpadt80
\clpadfb3\clpadb80
\clpadfl3\clpadl80
\clpadfr3\clpadr80
\clvertalt
\clbrdrb\brdrs\brdrw10\brdrcf2\clbrdrr\brdrs\brdrw10\brdrcf2\cellx6087
\pard\intbl\li80\ri90\sl200
{\plain\f4\fs18\cf2\ulc2
Codeine/Morphine
}
\cell
\pard\intbl\qc\li80\ri80\sl200
{\plain\f4\fs18\cf2\ulc2
2000 ng/ml
}
\cell
\row
\trowd\trleft5
\clpadft3\clpadt80
\clpadfb3\clpadb80
\clpadfl3\clpadl80
\clpadfr3\clpadr80
\clvertalt
\clbrdrb\brdrs\brdrw10\brdrcf2\clbrdrl\brdrs\brdrw10\brdrcf2\clbrdrr\brdrs\brdrw10\brdrcf2\cellx3705
\clpadft3\clpadt80
\clpadfb3\clpadb80
\clpadfl3\clpadl80
\clpadfr3\clpadr80
\clvertalt
\clbrdrb\brdrs\brdrw10\brdrcf2\clbrdrr\brdrs\brdrw10\brdrcf2\cellx6087
\pard\intbl\li80\ri90\sl200
{\plain\f4\fs18\cf2\ulc2
Hydrocodone/Hydromorphone
}
\cell
\pard\intbl\qc\li80\ri80\sl200
{\plain\f4\fs18\cf2\ulc2
300 ng/ml
}
\cell
\row
\trowd\trleft5
\clpadft3\clpadt80
\clpadfb3\clpadb80
\clpadfl3\clpadl80
\clpadfr3\clpadr80
\clvertalt
\clbrdrb\brdrs\brdrw10\brdrcf2\clbrdrl\brdrs\brdrw10\brdrcf2\clbrdrr\brdrs\brdrw10\brdrcf2\cellx3705
\clpadft3\clpadt80
\clpadfb3\clpadb80
\clpadfl3\clpadl80
\clpadfr3\clpadr80
\clvertalt
\clbrdrb\brdrs\brdrw10\brdrcf2\clbrdrr\brdrs\brdrw10\brdrcf2\cellx6087
\pard\intbl\li80\ri90\sl200
{\plain\f4\fs18\cf2\ulc2
Oxycodone/Oxymorphone
}
\cell
\pard\intbl\qc\li80\ri80\sl200
{\plain\f4\fs18\cf2\ulc2
100 ng/ml
}
\cell
\row
\trowd\trleft5
\clpadft3\clpadt80
\clpadfb3\clpadb80
\clpadfl3\clpadl80
\clpadfr3\clpadr80
\clvertalt
\clbrdrb\brdrs\brdrw10\brdrcf2\clbrdrl\brdrs\brdrw10\brdrcf2\clbrdrr\brdrs\brdrw10\brdrcf2\cellx3705
\clpadft3\clpadt80
\clpadfb3\clpadb80
\clpadfl3\clpadl80
\clpadfr3\clpadr80
\clvertalt
\clbrdrb\brdrs\brdrw10\brdrcf2\clbrdrr\brdrs\brdrw10\brdrcf2\cellx6087
\pard\intbl\li80\ri90\sl200
{\plain\f4\fs18\cf2\ulc2
6-Acetylmorphine
}
\cell
\pard\intbl\qc\li80\ri80\sl200
{\plain\f4\fs18\cf2\ulc2
10 ng/ml
}
\cell
\row
\trowd\trleft5
\clpadft3\clpadt80
\clpadfb3\clpadb80
\clpadfl3\clpadl80
\clpadfr3\clpadr80
\clvertalt
\clbrdrb\brdrs\brdrw10\brdrcf2\clbrdrl\brdrs\brdrw10\brdrcf2\clbrdrr\brdrs\brdrw10\brdrcf2\cellx3705
\clpadft3\clpadt80
\clpadfb3\clpadb80
\clpadfl3\clpadl80
\clpadfr3\clpadr80
\clvertalt
\clbrdrb\brdrs\brdrw10\brdrcf2\clbrdrr\brdrs\brdrw10\brdrcf2\cellx6087
\pard\intbl\li80\ri90\sl200
{\plain\f4\fs18\cf2\ulc2
Phencyclidine
}
\cell
\pard\intbl\qc\li80\ri80\sl200
{\plain\f4\fs18\cf2\ulc2
25 ng/ml
}
\cell
\row
\trowd\trleft5
\clpadft3\clpadt80
\clpadfb3\clpadb80
\clpadfl3\clpadl80
\clpadfr3\clpadr80
\clvertalt
\clbrdrb\brdrs\brdrw10\brdrcf2\clbrdrl\brdrs\brdrw10\brdrcf2\clbrdrr\brdrs\brdrw10\brdrcf2\cellx3705
\clpadft3\clpadt80
\clpadfb3\clpadb80
\clpadfl3\clpadl80
\clpadfr3\clpadr80
\clvertalt
\clbrdrb\brdrs\brdrw10\brdrcf2\clbrdrr\brdrs\brdrw10\brdrcf2\cellx6087
\pard\intbl\li80\ri90\sl200
{\plain\f4\fs18\cf2\ulc2
Amphetamine/Methamphetamine
}
\cell
\pard\intbl\qc\li80\ri80\sl200
{\plain\f4\fs18\cf2\ulc2
500 ng/ml
}
\cell
\row
\trowd\trleft5
\clpadft3\clpadt80
\clpadfb3\clpadb80
\clpadfl3\clpadl80
\clpadfr3\clpadr80
\clvertalt
\clbrdrb\brdrs\brdrw10\brdrcf2\clbrdrl\brdrs\brdrw10\brdrcf2\clbrdrr\brdrs\brdrw10\brdrcf2\cellx3705
\clpadft3\clpadt80
\clpadfb3\clpadb80
\clpadfl3\clpadl80
\clpadfr3\clpadr80
\clvertalt
\clbrdrb\brdrs\brdrw10\brdrcf2\clbrdrr\brdrs\brdrw10\brdrcf2\cellx6087
\pard\intbl\li80\ri90\sl200
{\plain\f4\fs18\cf2\ulc2
MDMA4/MDA5
}
\cell
\pard\intbl\qc\li80\ri80\sl200
{\plain\f4\fs18\cf2\ulc2
500 ng/ml
}
\cell
\row
\pard\sb180\qj\sl250\tx100
{\plain\f4\fs14\cf2\ulc2
1
}
{\plain\f4\fs21\cf2\ulc2
\tab
}
{\plain\f4\fs21\cf2\ulc2
For grouped analytes (i.e., two or more analytes that are in the same drug class and have the same initial test cutoff):
}
\par
\pard\qj\sl250
{\plain\f4\fs21\i\cf2\ulc2
Immunoassay
}
{\plain\f4\fs21\cf2\ulc2
: The test must be calibrated with one analyte from the group identified as the target analyte. The cross-reactivity of the immunoassay to the other analyte(s) within the group must be 80 percent or greater; if not, separate immunoassays must be used for the analytes within the group.
}
\par
\pard\qj\sl250
{\plain\f4\fs21\i\cf2\ulc2
Alternate technology
}
{\plain\f4\fs21\cf2\ulc2
: Either one analyte or all analytes from the group must be used for calibration, depending on the technology. At least one analyte within the group must have a concentration equal to or greater than the initial test cutoff or, alternatively, the sum of the analytes present (i.e., equal to or greater than the laboratory’s validated limit of quantification) must be equal to or greater than the initial test cutoff.
}
\par
\pard\qj\sl250\tx100
{\plain\f4\fs14\cf2\ulc2
2
}
{\plain\f4\fs21\cf2\ulc2
\tab
}
{\plain\f4\fs21\cf2\ulc2
An immunoassay must be calibrated with the target analyte, D-9-tetrahydrocannabinol-9-carboxylic acid (THCA).
}
\par
\pard\qj\sl250\tx100
{\plain\f4\fs14\cf2\ulc2
3
}
{\plain\f4\fs21\cf2\ulc2
\tab
}
{\plain\f4\fs21\i\cf2\ulc2
Alternate technology
}
{\plain\f4\fs21\cf2\ulc2
(THCA and benzoylecgonine): The confirmatory test cutoff must be used for an alternate technology initial test that is specific for the target analyte (i.e., 15 ng/mL for THCA, 100 ng/mL for benzoylecgonine).
}
\par
\pard\qj\sl250\tx100
{\plain\f4\fs14\cf2\ulc2
4
}
{\plain\f4\fs21\cf2\ulc2
\tab
}
{\plain\f4\fs21\cf2\ulc2
Methylenedioxymethamphetamine (MDMA).
}
\par
\pard\qj\sl250\tx100
{\plain\f4\fs14\cf2\ulc2
5
}
{\plain\f4\fs21\cf2\ulc2
\tab
}
{\plain\f4\fs21\cf2\ulc2
Methylenedioxyamphetamine (MDA).
}
\par
\pard\qj\sl250\tx340
{\plain\f4\fs21\cf2\ulc2
\tab
}
{\plain\f4\fs21\b\cf2\ulc2
157.7
}
{\plain\f4\fs21\b\cf2\ulc2
(2)
}
{\plain\f4\fs21\cf2\ulc2
}
{\plain\f4\fs21\cf2\ulc2
Reserved.
}
\par
\pard\keep\sl180
{\plain\f4\fs16\cf2
[
}
{\field{\*\fldinst HYPERLINK "https://www.legis.iowa.gov/docs/aco/arc/0219C.pdf"}{\fldrslt
{\plain\f4\fs16\b\cf2
ARC 0219C
}
}}
{\plain\f4\fs16\cf2
, IAB 7/25/12, effective 9/1/12;
}
{\field{\*\fldinst HYPERLINK "https://www.legis.iowa.gov/docs/aco/arc/5407C.pdf"}{\fldrslt
{\plain\f4\fs16\b\cf2
ARC 5407C
}
}}
{\plain\f4\fs16\cf2
, IAB 1/27/21, effective 3/3/21]
}
\par
\pard\qj\fi340\sl250
{\plain\f4\fs21\cf2
These rules are intended to implement Iowa Code section
}
{\field{\*\fldinst HYPERLINK "https://www.legis.iowa.gov/docs/ico/section/123.46.pdf"}{\fldrslt
{\plain\f4\fs21\cf2
123.46
}
}}
{\plain\f4\fs21\cf2
and chapter
}
{\field{\*\fldinst HYPERLINK "https://www.legis.iowa.gov/docs/ico/chapter/321J.pdf"}{\fldrslt
{\plain\f4\fs21\cf2
321J
}
}}
{\plain\f4\fs21\cf2
.
}
\par
\pard\qc\sl250
{\plain\f4\fs21\cf2
[Filed 4/2/07, Notice 9/13/06—published 4/25/07, effective 6/1/07]
}
\par
\pard\qc\sl250
{\plain\f4\fs21\cf2
[Filed emergency 12/21/07—published 1/16/08, effective 1/1/08]
}
\par
\pard\qc\sl250
{\plain\f4\fs21\cf2
[
}
{\field{\*\fldinst HYPERLINK "https://www.legis.iowa.gov/docs/aco/arc/7529B.pdf"}{\fldrslt
{\plain\f4\fs21\cf2
Filed ARC 7529B
}
}}
{\plain\f4\fs21\cf2
(
}
{\field{\*\fldinst HYPERLINK "https://www.legis.iowa.gov/docs/aco/arc/7020B.pdf"}{\fldrslt
{\plain\f4\fs21\cf2
Notice ARC 7020B
}
}}
{\plain\f4\fs21\cf2
, IAB 7/30/08), IAB 1/28/09, effective 4/1/09]
}
\par
\pard\qc\sl250
{\plain\f4\fs21\cf2
[
}
{\field{\*\fldinst HYPERLINK "https://www.legis.iowa.gov/docs/aco/arc/0219C.pdf"}{\fldrslt
{\plain\f4\fs21\cf2
Filed ARC 0219C
}
}}
{\plain\f4\fs21\cf2
(
}
{\field{\*\fldinst HYPERLINK "https://www.legis.iowa.gov/docs/aco/arc/0098C.pdf"}{\fldrslt
{\plain\f4\fs21\cf2
Notice ARC 0098C
}
}}
{\plain\f4\fs21\cf2
, IAB 4/18/12), IAB 7/25/12, effective 9/1/12]
}
\par
\pard\qc\sl250
{\plain\f4\fs21\cf2
[
}
{\field{\*\fldinst HYPERLINK "https://www.legis.iowa.gov/docs/aco/arc/5407C.pdf"}{\fldrslt
{\plain\f4\fs21\cf2
Filed ARC 5407C
}
}}
{\plain\f4\fs21\cf2
(
}
{\field{\*\fldinst HYPERLINK "https://www.legis.iowa.gov/docs/aco/arc/5295C.pdf"}{\fldrslt
{\plain\f4\fs21\cf2
Notice ARC 5295C
}
}}
{\plain\f4\fs21\cf2
, IAB 12/2/20), IAB 1/27/21, effective 3/3/21]
}
\par
\pard\sect
}